Quick project answer
Airport convention venues often need flexible room sizes without disrupting the finished floor. This checklist explains how to plan a movable partition installation using a top-hung system. It focuses on the confirmed EBUNGE approach: no continuous floor track and no operating hardware in the finished floor along the partition line. Use it to prepare questions, gather inputs and coordinate drawings before any partition installation work begins.
Start with the top-hung principle
The EBUNGE movable partition system is top-hung. That means the operating support is overhead, not in the floor. A partition installation planned this way does not require a continuous floor running track or operating hardware in the finished floor along the partition line. The floor remains physically uninterrupted by the maintained EBUNGE top-hung system.
This principle shapes early planning. The exact overhead route and support arrangement must be confirmed by the responsible project team from coordinated drawings. The exact route, junction arrangement, continuous overhead path and parking position must be confirmed from the coordinated project drawings.
Confirm the floor remains uninterrupted
For airport convention spaces, floor continuity matters. The floor is not cut or damaged for a floor track when a maintained EBUNGE top-hung system is used. That keeps the finished floor surface free of a continuous track along the partition line.
During a partition installation, the floor condition should be recorded before and after work. The confirmed fact is that the maintained top-hung system leaves the floor physically uninterrupted. Any other floor-related requirement must be checked against the coordinated project drawings.
Plan parking and stacking early
Panel parking style can be customized to the customer layout and project requirements, subject to coordinated drawings. A suitable approved parking arrangement can use the stacking area more compactly and coordinate with the space design. The exact track, support and panel layout still require project drawings.
For an airport convention partition installation, parking planning should begin with the room combination strategy. Consider where panels rest when the space is open, how that area relates to circulation and how the stacking zone fits the interior design. Do not assume a parking method until drawings confirm it.
Coordinate finish and care choices
Finish materials can be customized. Cleaning and maintenance methods vary with the selected finish. That means the finish choice and the care routine should be decided together, not separately.
Ask the project team to list the proposed finish for each face and edge condition. Then confirm the cleaning method that suits that finish. Because care methods vary, a single generic routine may not apply across all panels in one partition installation.
Review non-limiting applications
Movable partitions can be used wherever flexible space division, combination or reconfiguration is required. Application examples are not limiting. EBUNGE has completed many types of hotel-related movable-partition projects. Ballrooms, wedding halls and multifunction halls are non-limiting examples.
Airport convention centers may share similar needs: dividing a large hall, combining smaller rooms or reconfiguring a multifunction area. These are examples only. The same top-hung partition installation approach can be considered wherever flexible space division is required, subject to project drawings.
Gather buyer inputs before drawings
A smooth partition installation starts with clear inputs. The project team should collect room dimensions, intended room combinations, parking preferences and finish direction. These inputs feed the coordinated drawings.
Buyers should also confirm who approves the drawings and who checks the installed condition. Because the exact route, junction arrangement, continuous overhead path and parking position must be confirmed from the coordinated project drawings, early input reduces later rework.
Use a scannable pre-drawing checklist
- Confirm the partition line and the rooms it will divide or combine.
- Record the finished floor condition before any partition installation work.
- State that the intended system is top-hung with no continuous floor track.
- Identify the preferred parking style and stacking area for review.
- List finish preferences and the care method for each finish.
- Collect room combination scenarios for the coordinated drawings.
- Confirm who reviews and approves the final drawings.
Drawing approval points to verify
Before production or site work, review the coordinated drawings for the overhead path, support and panel layout. The exact route, junction arrangement, continuous overhead path and parking position must be confirmed from the coordinated project drawings.
Use the table below to track approval items. It is a planning aid, not a substitute for project-specific drawings.
| Approval item | What to confirm | Status |
|---|---|---|
| Overhead path | Continuous overhead route shown on drawings | Pending |
| Parking position | Stacking area and panel parking style | Pending |
| Floor condition | No continuous floor track along partition line | Pending |
| Finish schedule | Custom finish choices and care method | Pending |
| Drawing approval | Signed coordinated drawings | Pending |
Common planning questions
Does a partition installation require a floor track?
No continuous floor running track or operating hardware is required in the finished floor along the partition line for the maintained EBUNGE top-hung system. The floor is not cut or damaged for a floor track.
Can the floor remain uninterrupted after partition installation?
Yes. The floor remains physically uninterrupted by the maintained EBUNGE top-hung system. This is a confirmed feature of the top-hung approach.
How is panel parking decided?
Panel parking style can be customized to the customer layout and project requirements, subject to coordinated drawings. A suitable approved parking arrangement can use the stacking area more compactly and coordinate with the space design.
Can finishes be customized for an airport convention partition installation?
Finish materials can be customized. Cleaning and maintenance methods vary with the selected finish, so the care routine should match the chosen finish.
Where can movable partitions be used?
Movable partitions can be used wherever flexible space division, combination or reconfiguration is required. Application examples are not limiting. EBUNGE has completed many types of hotel-related movable-partition projects, including ballrooms, wedding halls and multifunction halls as non-limiting examples.
Link planning to product and project references
For product context, review the movable partition product range. For project context, review the completed project references. These pages help buyers frame questions before a partition installation drawing review.
Keep every product statement tied to confirmed facts.
Final checks before approval
Before signing off, confirm that the coordinated drawings show the overhead path, support and parking position. Confirm that the floor will remain uninterrupted by the maintained top-hung system. Confirm the finish schedule and the care method for each finish.
Then confirm who will review the installed condition against the approved drawings. A disciplined partition installation checklist helps the airport convention team keep the floor, parking and finish decisions aligned from planning through handover.
Continue Exploring
More Installation and Maintenance Guides
- Newer guideCommunity Hall Movable Partition Installation: Speaker Array
- Earlier guideSchool Auditorium Partition Track: Cyclorama Coordination
- Related guideHow Contractors Sequence Movable Partition Frames Before Ceiling Grid
- Related guideHow Contractors Build a Movable Partition Installation Crew Plan