When your project team prepares a contractor tender for an office meeting suite, the movable partition stacking pocket is often the most coordination-sensitive element. The phrase office meeting suite partition stacking pocket drawings tender refers to the set of drawings that define where panels park, how they travel, and how the ceiling and floor interfaces are built. Without clear drawings, contractors may price differently, leading to budget surprises or site conflicts.
EBUNGE movable partition panels are individually movable and suspended from a top track. They cross the opening without a floor track, which simplifies floor finishes but places greater importance on the overhead route and stacking area. In a tender, you need drawings that show the full path from the opening to the parking position, including any turns. This article explains which drawings you should request and how to review them with project-specific evidence.
Understanding the Movable Partition System for Tender Planning
Before diving into drawing specifics, it helps to understand the system’s basic characteristics. EBUNGE movable partitions are top-hung, meaning each panel is supported from an overhead track. There is no continuous floor running track or floor hardware along the partition line. This design allows a clean floor surface when the partition is stored, which is often desirable in meeting suites.

Panels park at a planned stacking position, which is customized to your layout. The exact route, junction arrangement, continuous overhead path and parking position must be confirmed from the coordinated project drawings. For a contractor tender, you must confirm that the proposed stacking pocket fits within the architectural constraints and that the track route is continuous and supported.
Key Components Shown in Drawings
Drawings for a movable partition system typically include the following components:
- Plan views showing the partition line, stacking pocket, and track route.
- Section details illustrating the ceiling suspension and track profile.
- Elevation views indicating panel heights and finishes.
- Stacking pocket dimensions including depth, width, and clearance.
- Track route diagrams for straight, turning, and stacking paths.
Each of these drawings must be reviewed in the context of your specific project. The suitability of each route and parking arrangement depends on the approved layout, circulation, ceiling interfaces and operating sequence.
Essential Drawings for the Stacking Pocket in a Tender Package
Share the opening dimensions, room layout and intended operating sequence for review.
To ensure accurate pricing and installation, your tender package should include the following drawings:
1. Reflected Ceiling Plan (RCP) with Track Route
The RCP is the most critical drawing for the stacking pocket. It shows the ceiling grid, light fixtures, HVAC diffusers, and other overhead elements. The track route must be coordinated with these items to avoid clashes. The RCP should clearly indicate the path from the partition opening to the stacking pocket, including any curves or switches. For EBUNGE systems, the route must be continuous and supported along its entire length.
2. Stacking Pocket Plan and Section
This drawing details the pocket itself: its length, depth, and how panels are stored. It should show the pocket’s relationship to adjacent walls, columns, and doors. A section view is essential to understand the ceiling height inside the pocket and any bulkhead requirements. The stacking pocket may be designed to accommodate a specific number of panels, which depends on the width of the opening and panel dimensions. These dimensions must be confirmed for your project.
3. Partition Elevation with Finish Indications
Elevations show the partition’s appearance when extended and stored. They indicate finish options such as laminate, melamine, fabric, leather, glass, or other approved surfaces. For tender, you need to specify the finish on both faces and any glazing or pass-door requirements. The elevation drawing helps contractors understand the scope of supply and installation.
4. Track and Suspension Details
These details show how the track is fixed to the building structure. The drawings should indicate the track profile, hanger spacing, and connection to the ceiling.
5. Door and Interface Details
If the partition includes a pass-door, you need detailed drawings showing the door frame, swing, and hardware. The interface between the partition and adjacent walls, floor, and ceiling must be detailed to ensure proper sealing and operation.
How to Review Stacking Pocket Drawings for Tender
Reviewing drawings is not just about checking dimensions. You must ensure that the drawings are consistent and buildable. Here are steps to follow:
Check the Route Continuity
Verify that the track route is continuous from the opening to the stacking pocket. There must be no gaps or obstructions. EBUNGE panels can follow straight, turning, and stacking routes, but each path must be reviewed from the layout. If your layout requires a turn, the drawings must show the switch or curve details.
Confirm Stacking Pocket Clearances
The stacking pocket must have enough space for the panels to park without interference. This includes vertical clearance for the panels and any track components. The pocket depth must accommodate the panel thickness and any seals. Visible references can support layout discussion but do not verify hidden construction or performance.
Coordinate with Other Trades
The stacking pocket often sits above a ceiling or within a bulkhead. Coordinate with mechanical, electrical, and plumbing (MEP) drawings to avoid clashes. The track may need to pass under ductwork or above light fixtures. Cost and maintenance requirements depend on the selected configuration, finish and project conditions and require project-specific confirmation.

Review Structural Support
The exact overhead route and support arrangement must be confirmed by the responsible project team from coordinated drawings. The drawings should indicate the loads and support points. This is a project-specific engineering review that must be done by qualified professionals.
Project Documentation and Coordination for Tender
Beyond the drawings themselves, your tender package should include project documentation that clarifies responsibilities and interfaces. This includes specifications, schedules, and coordination protocols.
Specifications for Materials and Finishes
Write clear specifications for the partition system, including panel construction, track material, and finishes. EBUNGE offers a range of finishes, but you must select the ones appropriate for your project. The specification should state that the system is top-hung and floor-track-free, to avoid confusion.
Review the ceiling interface, panel route and stacking position together.
Coordination Meetings and Submittals
Plan for coordination meetings with the partition supplier, contractor, and other stakeholders. Require the supplier to submit shop drawings and product data for approval before fabrication. These submittals should include detailed stacking pocket drawings that match the architectural intent.
Clarify Pass-Door and Access Requirements
If a pass-door is required, specify its size, swing direction, and hardware. The door must be integrated into the partition panel without compromising the system’s operation.
Common Pitfalls in Stacking Pocket Tender Drawings
Avoid these mistakes when preparing or reviewing drawings:
- Omitting the stacking pocket entirely – Some tenders only show the partition line, leaving the parking area undefined.
- Assuming a straight route – If your layout requires a turn, the drawings must show it.
- Ignoring ceiling obstructions – The track route must avoid lights, sprinklers, and ducts. A clash can delay installation.
- Specify the exact finish for each face.
Frequently Asked Questions
What is a stacking pocket in a movable partition system?
A stacking pocket is the designated area where movable partition panels are stored when not in use. It is typically a recess or alcove that accommodates the panels in a stacked configuration. The pocket’s design must allow for easy movement and access.
Why is the stacking pocket important in a contractor tender?
If not clearly specified, contractors may make different assumptions, leading to price variations and coordination issues.
Do EBUNGE movable partitions require a floor track?
No, EBUNGE movable partitions are top-hung and move without a continuous floor running track or floor hardware along the partition line. This is a key feature that simplifies floor finishes and accessibility.
What drawings are essential for specifying the stacking pocket?
Essential drawings include a reflected ceiling plan with the track route, a stacking pocket plan and section, partition elevations, track and suspension details, and door/interface details. These drawings must be coordinated with other trades.
How can I ensure the stacking pocket drawings are accurate for tender?

Work with an experienced movable partition supplier early in the design process. Provide them with your architectural drawings and discuss your requirements. They can produce detailed shop drawings that are tailored to your project.
Can the stacking pocket accommodate a turning route?
Yes, EBUNGE systems can be designed for straight, turning, and stacking routes.
Conclusion and Next Steps
Specifying office meeting suite partition stacking pocket drawings for a contractor tender requires a clear understanding of the system and careful coordination.
Remember that every project is unique. EBUNGE’s team can assist you in reviewing your layout and preparing the necessary documentation. Contact EBUNGE to discuss your project and request a detailed review of your stacking pocket drawings.
For more information about movable partition systems, visit our movable partition wall page. You can also explore our project portfolio to see examples of completed installations.
Continue Exploring
More Cost and Planning Guides
- Newer guideAuditorium Partition Track Drawings Near Fire Alarm Pull Stations
- Earlier guideWhat Drawings Specify Hotel Banquet Partition Stacking Pockets at Ceiling-Mounted Projector Lift Zones
- Related guideWhat Drawings Specify Community Hall Partition Track at Ceiling-Mounted Ladder Storage Racks
- Related guideWhat Drawings Specify Function Room Partition Stacking Pockets at Ceiling-Mounted Rigging Point Zones